Fuel cells, with headroom built in
Hydrogen fuel cells of 80 kW and up total as much as 1.76 MW installed behind the 1.5 MW rating. That margin is engineered redundancy: the system holds its rated output without ever asking every cell to do so.
A megawatt-class hydrogen power plant in a 40-foot container. It arrives factory-integrated, sits on a concrete pad, and delivers primary and backup power with no combustion, no transfer switch, and no CO₂ emissions permits.
Just add hydrogen. You're ready to go.
Top module rating
Fuel cells installed
Standard battery
On battery alone at full load
A standby generator has to start; a UPS has to hand off. EmPower does neither, because its fuel cells are always online. There is no transfer switch and no gap between grid power and backup power. And if the hydrogen supply is ever interrupted, the battery array alone carries the full load for about 30 minutes.
Hydrogen fuel cells of 80 kW and up total as much as 1.76 MW installed behind the 1.5 MW rating. That margin is engineered redundancy: the system holds its rated output without ever asking every cell to do so.
A 720 kWh lithium-ion array is standard, configurable from 500 to 1,200 kWh. It absorbs load swings and, if hydrogen supply is interrupted, carries the full load alone for about 30 minutes.
Up to 1.5 MW of inverters deliver AC at 120/208 and 480 Delta. High-efficiency heat exchangers are built in, with connections to your facility's exchangers.
Everything ships in a single 40-foot container. Site preparation is a concrete pad and your electrical connection. Then add hydrogen.
About 1 high-pressure Virtual Pipeline unit, at 1,200 kg and 350 bar each.
The 720 kWh battery alone carries a 1.5 MW load.

Guaranteed uptime, online months before a utility interconnect. EmPower installs outside the building quickly, or inside if needed, connected to existing super-computer cooling systems.
Avoid power disruptions and grid-upgrade delays, expand capacity as operations grow, and keep full control over your own energy supply. One machine for both everyday power and outage protection.
Bypass grid limitations entirely. Megawatt-class power behind the chargers means a site can open where the utility can't serve it yet, and scale without waiting on the feeder.

The team behind EmPower has been putting fuel cells under data center loads since 2017, when they worked with NREL to prove that hydrogen fuel cells could power a data center, and then with Microsoft and others to demonstrate that the approach scales.
EmPower is that heritage as a product: the fuel cells, battery, inverters and thermal systems integrated, tested and delivered as one machine.
| Topic | EmPower | Diesel generator |
|---|---|---|
| Emissions | Pure water; no CO₂ emissions permits required | CO₂, NOx and particulates; permitted and increasingly restricted |
| Noise | Near-silent, low heat signature | Engine noise constrains siting and overnight operation |
| Efficiency | Over 50% more efficient as primary or backup power | Baseline; efficiency falls further at partial load |
| Fuel logistics | Hydrogen stores indefinitely without degrading | Degrades in storage; needs polishing, treatment and rotation |
| Load response | Battery buffer absorbs surges instantly | Governor lag on step loads; oversizing is the common workaround |
Every figure here comes from the EmPower data sheet. We size the module, the storage and the delivery schedule around your load.
| Module sizes | 250 kW / 750 kW / 1 MW / 1.5 MW |
|---|---|
| Fuel cell architecture | 80 kW+ cells, up to 1.76 MW installed |
| Inverters | Up to 1.5 MW |
| Battery | 720 kWh standard; 500–1,200 kWh configurable |
| Battery bridge | ~30 min at full load if hydrogen supply is interrupted |
| Topology | Fuel cells always online: UPS and generator in one, no transfer switch |
| AC output | 120/208, 480 Delta |
|---|
| Hydrogen quality | 99.999% purity |
|---|---|
| Delivered energy | 12–20 kWh per kg |
| Usage at continuous load | 1.5 MW: ~100 kg/hr 1 MW: ~67 kg/hr 500 kW: ~34 kg/hr 250 kW: ~17 kg/hr |
| Fuel storage | Hydrogen stores indefinitely without degrading, unlike diesel |
| Container | 40' × 8' × 11'6" (12.2 × 2.44 × 3.5 m) |
|---|---|
| Installation | One piece, factory-integrated; concrete pad; heat exchanger connections to facility systems |
| Efficiency | Over 50% more efficient than diesel as primary or backup power |
| Permitting | No CO₂ emissions permits required |
Tell us your load profile and site. We'll size the module, plan the hydrogen supply, and quote the whole installation, delivered as one piece.